Loading...
HomeMy WebLinkAbout _ 4.11(b)--Award BS No. 5368 Foothill Water Treatment Plant Generator GI �" Y � F � � � ° � � � " � � CITY OF REDDING REPORT TO THE CITY COUNCIL MEETING DATE: June 20,2023 FROM: Chuck Aukland,Public ITEM NO. 4.11(b} Works Director ***APPROVED BY*** � ��n � .�.._ s.N,.�� � � � ��� ukl�n�l,H'ciblic Wc�aks L'��reGt ' 6,^'8/7423 ry ip}�in,�C"i ana � 6,i13/2423 caulcland@ci.redding.ca.us btippin@cityofredding.org SUBJECT: 4.11(b)--Award Bid Sched�ule No. 5368 (Job Order No. 2638) Foothill Water Treatment Plant Generator Project, Accept Grant Funds and Adopt Resolution Appropriating Funds Recommendation Authorize the following actions relative to Bid Schedule No. 5368 (Job No. 2638) Foothill Water Treatment Plant Generator Project: (1) Award to SnL Group, Inc., in the amount of$2,592,275; (2) Approve an additional $3'75,000 to cover the cost of administration and inspection fees; and$240,000 for project development costs; (3) Approve $280,000 to provide construction contingency funding; (4) Autharize the City Manager to approve additional increases in either the construction management or construction contingency amounts up to a total of$50,000; (5) Accept grant funds awarded to the City of Redding for the Foothill Water Treatment Plant Generator; (6) Adopt Resolution approving and adopting the 90`h Amendment to the City Budget Resolution No. 2021-078 appropriating $1,967,840 in grant funds for the project; and (7) Find that the Project is categorically exempt from review under the California Environmental Quality Act, pursuant to Section 15301 - Existing Facilities and 15303 - New Construction or Conversion of Small Structures. Fiscal Impact The Foothill Water Treatment P1ant Generator Project (Project) is being funded by the Water Utility and the Federal Emergency Management Agency (FEMA) through its Hazard Mitigation Grant Program (HIVIGP). The City Council (Council) affirmed submission of the HMGP application for this project on October 16, 2018. FEMA separated the project into two phases prior to obligating funds. Phase 1 includes project management, environmental planning, and design development through the 70 percent design stage. Phase 2 includes completion of the design, environmental permitting, construction, and project closeout. FEMA has awarded grants to fund up to $1,844,848.50 for project costs and $122,898 for grant management costs associated with the project to date. Staff plans to request additional grant funds from FEMA for Report to Redding City Council June 13,2023 Re: 4.11(b)--Award BS No. 5368 Foothill Water Treatment Plant Generator Page 2 up to 75 percent of the allowable project costs. The remaining costs for the project wi11 be funded by the Water Utility. The Water Utility has sufficient budget to cover its share of this project and funding the project will not impact other activities or projects. Cost SummaN Item Estimated Pro'ect Develo ment Costs $240,000 Construction Contract+ Contin enc $2,872,2'75 Contract Administration, Ins ection, Testin $375,000 Additional Cit Mana er Authorit $50,000 Total Pro'ect Costs $3,53�,2�5 Project cost components are estimates and some shifting of the project development, construction management, and construction contingency funds may be necessary to balance the project within the approved budget. Alternative Action Council may choose not to award the bid for the project and provide staff with alternate direction. If the project is not awarded, then there will be a greater risk of an outage at the Foothill Water Treatment Plant, d�uring which time the treatment plant will not be able to supply safe drinking water, meet fire suppression demands, or supply the Redding Power Plant water to operate, decreasing reliability for City of Redding (City) customers. Background/Analysis The Foothill Water Treatment Plant (FWTP) is the City's largest and primary water supply. It provides more than half of the City's water supply during average and peak demands by treating water pumped from the Sacramento River. It is currently the only treatment facility (including water and wastewater) in the City that does not have a back-up generator. Continuous operation of the FWTP is needed to supply safe drinking water, meet fire suppression demands, and supply the Redding Power Plant water to operate. This project will install a new standby generator and automatic transfer switch at the Foothill Water Treatment Plant. The generator will provide a backup power source and mitigate the risk of an outage and deficient water supply in the City during an emergency or power outage at the FWTP. The project also includes replacement of two existing transformers and switchboards at the treatment plant with a single new transformer and main switchboard, for use with the new generator and automatic transfer switch. Additional site improvements in the project will include construction of concrete pads and retaining walls, asphalt concrete pavement around the generator area, and construction of a new shade structure to protect the new electrical equipment. Attached is a tabulation of bids received and opened on May 18, 2023, for construction of the project. The low bid in the amount of $2,592,275 was reeeived from SnL Group, Inc., of Redding, California. The engineer's estimate was $2,505,8'75. Total project development costs for this project are estimated to be $240,000. Projeet development costs include engineering, grant applications and management, surveying, right-of-way, environmental, consultant services, and permit fees. Report to Redding City Council June 13,2023 Re: 4.11(b)--Award BS No. 5368 Foothill Water Treatment Plant Generator Page 3 Environmental Review Staff has determined that the project qualifies as categorically exempt from environmental review under California Environmental Quality Act Guidelines, pursuant to Sections 15301 - Existing Facilities and 15303 - New Construction or Conversion of Small Structures. Class 1 exemptions include the operation, repair, maintenance, or minor alteration of existing facilities, structures, or equipment involving negligible or no expansion of use. The new backup generator and associated electrical equipment will be installed at the existing facility, and the project does not involve expansion of facility use. The project area has been reviewed for sensitive resources and will not have an effect on biological or cultural resources such as threatened or endangered species or their habitats, sensitive vegetation communities, tribal lands, or tribal cultural resources. The project has no potential to have a significant effect on the environment. On May 31, 2022, FEMA found that the project is categorically excluded from environmental review under the National Environmental Policy Act, pursuant to FEMA Categorical Exclusion N18 - Federal Assistance for Construction or Installation of Structures, Facilities, or Equipment to Ensure Continuity of Operations. Council Priority/City Manager Goals This agenda item is a routine operational item. Attachments ^Location Map ^Bid Tabulation ^Notice of Exemption NEPA REC_FEMA Resolution No 90 w � � �� _� � - � ' � � _ � � � �<" - \ EUREKA WAY(SR 299W) z _ � 0��� � y � % �� � , � a �r �� ���� � � �� �G ��� �. �� �� m - � � � ���. PROJ�CT �� � R,Es�;�� R� �, �� �. ;�� � , � �y LOCATION � � � � �� �� �� ��� � � H �. , ���� ��NOT pAr �'� �o� � 3151� FOOT�iILL BLVD �• �` � ���� s � �' REDDING, �A 96001 �� � o �� �`� � o r�i�oMaARv wni,4� � z 9��., � �, � TONE P'- -� y. � r � c�zFEi�s � � z =� � : _ � � � F�pT1-11LLBL�� � � � ��" - ���� �; ➢ � �. � � � 2 �' � ➢ �" _-- � � � ; � �_________ �--� � jf O ' � ° �� � �,.� � � � � � S�P51P / .����� ����_-— �, , �"�----Uf j FOOTHILL WATER � ��� � c� , , � �'. � , A � ��- TREATMENT P�ANT ��! ' MANZANITA � j � � E�FIvIENTARY - � ��' � 1 � � ;- SCH�OL � �� ��/ � � � �' � J� �� �� ` p�lE � l �� �� ,CRP�F�RO � � � ,/� _ � �� -��:��--�--'' T , �� � ; �, � � , �� � � , ,. � �� �' �� �.�� -5 J � q!� �. ' 2 �� c� w���, � - y � ,;.. - - � A � � �Z � � �,, "., , ; � ... � a ; .' �.�_.' �'�. � �� ; � .' � C����,�R'„' � g� � � , �� � ' �, ' " � � '' o � � � �, � � � g� � �, � �� � , � � � AG� � , o � PL r � ��� � � � � ir � � � � - ��. . wy�� � � - � , y N�R� -� ' % � � � OS��� � � � �� � � �� ' c�AC,RPM �. � � , , c�� ' � SOUTN S� - B � � �N����� �� � � , / �q � ' `� i e���� - � � ��oF REoo FWTP C�ENERATOI� � � CITY OF R�DDING LOCATION MAP p� � ��Q ENGINEERING DEPARTMENT DESIGNED: KURT MAIRE, PE SCALE: 1" = 500' ��Foa PREPARED: KURT MAIRE, PE DATE: FEB 21, 2022 BID TABULATION FOR: Foothill Water Treatment Plant Generator Bid Schedule No.: 5368 ENGINEER'S EST Sn�Grou Inc RTA Construction 5/18/2023 U N IT U N IT U N IT ITEM DESCRIPTION UNIT QTY PRICE TOTA� PRICE TOTA� PRICE TOTA� 1 Water Pollution Control Plan LS 1 $5,750.00 $5,750.00 $1,250.00 $1,250.00 $5,000.00 $5,000.00 2 Demolition �S 1 $25,000.00 $25,000.00 $83,400.00 $83,400.00 $80,000.00 $80,000.00 3 Excavation (Unclassified) CY 500 $100.00 $50,000.00 $78.00 $39,000.00 $84.00 $42,000.00 4 Conduits and Conductors �S 1 $301,400.00 $301,400.00 $474,150.00 $474,150.00 $612,000.00 $612,000.00 5 Concrete Pads (Reinforced) CY 50 $1,250.00 $62,500.00 $700.00 $35,000.00 $3,090.00 $154,500.00 6 Concrete Curb �F 100 $55.00 $5,500.00 $95.00 $9,500.00 $286.00 $28,600.00 7 Crushed Gravel CY 10 $65.00 $650.00 $840.00 $8,400.00 $675.00 $6,750.00 8 Main Switcheboard �S 1 $155,000.00 $155,000.00 $150,000.00 $150,000.00 $120,000.00 $120,000.00 9 Distribution Panelboard A LS 1 $117,500.00 $117,500.00 $127,000.00 $127,000.00 $144,000.00 $144,000.00 10 Distribution Panelboard B �S 1 $117,500.00 $117,500.00 $111,000.00 $111,000.00 $137,000.00 $137,000.00 11 Standby Generator LS 1 $1,275,000.00 $1,275,000.00 $1,041,000.00 $1,041,000.00 $1,206,000.00 $1,206,000.00 12 Automatic Transfer Switch �S 1 $80,000.00 $80,000.00 $74,775.00 $74,775.00 $74,000.00 $74,000.00 13 Light Pole (20' and Luminaire), EA EA 1 $3,500.00 $3,500.00 $5,450.00 $5,450.00 $9,300.00 $9,300.00 14 Retaining Wall (Concrete) �F 135 $685.00 $92,475.00 $985.00 $132,975.00 $1,780.00 $240,300.00 15 Handrail LF 60 $225.00 $13,500.00 $300.00 $18,000.00 $440.00 $26,400.00 16 Shade Structure �S 1 $99,620.00 $99,620.00 $223,250.00 $223,250.00 $246,000.00 $246,000.00 17 Asphalt Concrete Pavement SF 4500 $18.00 $81,000.00 $8.50 $38,250.00 $11.00 $49,500.00 18 Relocate Fire Hydrant Assembly EA 1 $19,980.00 $19,980.00 $19,875.00 $19,875.00 $13,000.00 $13,000.00 TOTAL -CONTRACT ITEMS $2,505,875.00 $2,592,275.00 $3,194,350.00 Page 1 of 2 BID TABULATION FOR: Foothill Water Treatment Plant Generator Bid Schedule No.: 5368 AVERAGES 5/18/2023 U N IT ITEM DESCRIPTION UNIT QTY PRICE 1 Water Pollution Control Plan LS 1 $3,125.00 2 Demolition �S 1 $81,700.00 3 Excavation (Unclassified) CY 500 $81.00 4 Conduits and Conductors �S 1 $543,075.00 5 Concrete Pads (Reinforced) CY 50 $1,895.00 6 Concrete Curb �F 100 $190.50 7 Crushed Gravel CY 10 $757.50 8 Main Switcheboard �S 1 $135,000.00 9 Distribution Panelboard A LS 1 $135,500.00 10 Distribution Panelboard B �S 1 $124,000.00 11 Standby Generator LS 1 $1,123,500.00 12 Automatic Transfer Switch �S 1 $74,387.50 13 Light Pole (20' and Luminaire), EA EA 1 $7,375.00 14 Retaining Wall (Concrete) �F 135 $1,382.50 15 Handrail LF 60 $370.00 16 Shade Structure �S 1 $234,625.00 17 Asphalt Concrete Pavement SF 4500 $9.75 18 Relocate Fire Hydrant Assembly EA 1 $16,437.50 TOTAL -CONTRACT ITEMS $2,893,312.50 Page2of2 �QTICE OF EXEMPTION TO: ❑ Office of Planning and Research FRo1vt: City af Redding 1400 Tenth Street;Room 121 Fublic Works Department Sacramenta,CA 95814 777 Cypress Avenue Redding, CA 96001 � Shasta County Clerk County o£Shasta P.�.Box 990880, 1643 Market Str�et Redding, CA�6099-Q880 Project Title: Foathill Water Treatment Plant<Generator 1'roject J:O.#2b38-12 Praject Location—Speci�c: 3145 Foothill Boulevard Project Locatian—City:Reddin� Project Locatian—County: Shasta Description af Project: The Citv of Reddin� will install a standby generator at the Foatilill Water Treatment Flant �FWTP) The FWTP is a critical facilitv and contlnuous power is needed to sup�lv safe drinking; watar meet fire suppression demands, and supply water far the Reddin� Power Plant. Wark will include the installation af a new structurallv reinforced concrete �-enerator pad �enerator retaining walls fuel tank saund and weather enclosure alectrical canduit transforrner transfer switch switehboard electrlcal improvements miscellaneaus surface repair shade structure, fencing and aernolition of the existin� electrical equipment Work will involve trenehin� and minor excavation.All work will occur withln the public facilii�properiy. Name ofPublic Agency Agpraving Project: City ofReddin� Name of Person or Agency Carrying Out Project.Kurt Maire.Pra�ect Engineer Exempt Status: (check�ne) ❑ Ministerial [Section 21080(b)(1}; 152b8] ❑ Declared Emergency[Section 21080(b}(3); 15269(a}] ❑ Emergency Project [Sectian 21080(b)�4); 15269(b)] � Statutory Exernptians. State cade number. ❑ Common Sense Examption(This praject does not fall within an exempt class;but it can be seen with certainty that there is no passibility that the activity may have a significant effeet on the environment(14 CCR 1`5601[b]j3]}. � Categorical Exemption. State type and section number: Sec. 15301. Existin�Facilities& 15303.New Construction or Conversion of Small Structures. Based on an exaan'rnation ofthis proposal and supporting inforrnation,the following statements are true and exceptions do not,apply: • If this project falls within an exernpt class 3,4,5,6;or I 1,it does nat impact an environmental resource of hazardaus or critic�l concern where designated,precrsely-mapped,and officiatly adopted pursuant ta law; + There will not be a significant cumulative effect by tliis praject and successive projects of the same type in the same place,over time. • T(tere is not a reasonable possibility tltat the project wiil have a significant efFect on the environment due to unusual ciroumstances. * This project does not darnage a scenic resource within an officially designated state scenic ltighway; • This pro�ect is nat located on a site included on any list compiled pursuant to Govt.Cade§56962.5("Cor�ese List") • This project daes noY;cause a substantial adverse change in the s'rgnificance of a liistorical resource. Reasans why project is-exerngt: Class 1 exemptions include the operation, repair maintenance or minor alteration of existiin� facilities. structures, or equipmenti invalvin� ne�ligible or no expansian of use The new backu�generator and assaciated eiectrical equipment wi11 be installed at the existin� facility and the praject daes not involve expansian of facility use. The �roject has been reviewed for sensitive resources such as threatened ar endan�ered species or their habitats, sensitive ve�etatian communities tribal lands or tribal cultural resources The proiect has na�otential to have a si�nificanY effect on the environrnent. Lead Agency Contact Persona Amber'Kellev Telephonem 530:225.404b If Filed by Applicant: 1. Attach certified document of exernption finding. 2. Has a notice of exemptian been fled by the public agency approving the project? o Yes oNc� Signature: � ��'°�- .-�'- � � ����,�`' Date: � Title. Environmental Com liance Ma � er ❑ Signed by Lead Agency Date received for filing at OPR: ❑ 5igned by Applicant 06/10(2022 F L Y Y REG01 16:34:59 REcoR oF ENv' oNnnENTAL coNsiDE�ATio�( Ec) Project HMGP-4382-0004-CA(4382-143-04)(2) Title� Foothill Water Treatment Plant Generator(Phase 2) NEPA DETER INATION Non Compliant Flag: No EA Draft Date: EA Final date: EA Public Notice Date: EA Fonsi Level: CATEX EIS Notice of Intent EIS ROD Date: Comment The proposed project is the installation of a new standby generator at Gity of Redding's Foothill Water Treatment Rlant(FWTP).It will also include replacement of the two existing transformers and switchboards at the FWTP with a single new transformer and switchboard.There will be excavation to a depth of 2 feet for the new generator(50 x 15ft)and transformer(10 x 10ft)concrete pads and approximately 200 feet of shallow open trenching for conduits.Cast-in-place concrete pads reinforced with steel rebar will be required for the new generator and the new transformer.The new generator pad will be approximately 11 feet wide by 46 feet long.The transformer pad is approximately 6 feet by 6 feet. The staging area will be on the property(40.58168Q-122.418772}. FEMA has determined that this project is Categorically Excluded from the need to prepare either an Environmental Impact Statement or Environmental Assessment in accordance with FEMA Instruetion 108-1-1 and FEMA Directive 108-1-1 as authorized by DHS Instruction Manual 023-01-001-01,Revision 1.Categorical Exclusion N18 has been applied.Particular attention should be given to the project conditions before and during project implementation.Failure to comply with these conditions may jeopardize federal assistance including funding. -joneal4-05/31/2022 18:27:02 GMT CATEX CATEGORIES Catex Category Code Description Selected "n18 ('n18)Federal Assistance for Construction or Installation of Structures, Yes Facilities,or Equipment to Ensure Continuity of Operations.Federal assistance for the construction or installation of ineasures for the purpose of ensuring the continuity of operations during incidents such as emergencies,disasters, flooding,and power outages involving Bess than one acre of ground disturbance. Examples include the installation af generators,installation of storage tanks of up to 10,000 gallons,installation of pumps,construction of structures to house emergency equipment,and utility line installation.This CATEX covers associated ground disturbing activities,such as trenching,excavation,and vegetation removal of less than one acre,as well as modification of existing structures. EXTRAORDINARY Extraordinary Circumstance Code Description Selected? No Extraordinary Circumstances were seBected ENVIRO ENTAL LAW/EXECUTIVE ORQER Environmental Lawl Executive Order Status Description Comment Clean Air Act(CAA) Completed Project is located in an attainment area- The project is located in Shasta County that is Review conclud�d within an attainment area for all criteria poilutants according to the U.S.Environmental Protection Agency(USEPA) NOTE:All times are GMT using a 24-haur clock. Page 1 of 4 06/10(2022 F L Y Y REG01 16:34:59 REcoR oF ENv' oNnnENTAL coNsiDE�ATio�( Ec) Project HMGP-4382-0004-CA(4382-143-04)(2) Title� Foothill Water Treatment Plant Generator(Phase 2) Environmental Law/ Executive Order Status Description Comment (https:!/www3.epa.gov/ai rq uaiitylg reenboo Wancl. html),updated June 30th,2021.The SC?W associated with this undertaking is exempt from a conformity determination under the General Conformity Rule.-joneal4-05l31/2022 18:13:02 GMT Coastal Barrier Resources Act Gompleted Praject is raot on or connected ta GBRA Unit (CBRA) or otherwise protected area-Review concluded Clean Water Act(CWA) Completed Project would not affect any water of the U.S. The National Wetlands Inventory(NWI)does not -Fieview concluded identify any streams,waterbodies,or wetiands in the project area.This project would not affect Waters of the U.S.;therefore,coordination with the U.S.Army Gorps of Engineers is not required.-joneal4-05/3i/2022 18:12:32 GMT Coastal Zone Management Act Completed Project is not located in a coastal zone area The project site is not in a coastal zone area and (C2MA) and does not affect a coastal zone area- would not affect a coastal zone area.The project Fievisw concluded site is more than 94 miles inland fram the California coastiine.-joneal4-05(31/2022 18:12:45 GMT Executive Order 11988- Completed No effect on floodpBain/flood levels and Based on the FEMA Flood Insurance Rate Map Floodplains project outside floodplain-Review concluded (FIRM)panel 06089G1535G(effective 03/17/2011),all project activities would occur in Zone X,an area of minimal flood hazard.The&- Step process for floodpBains is not required.- joneal4-05l31/2022 18:14:07 GMT Executive Order 11990- Completed No effects on wetlands and project outside Based on a review of the USFWS National Wetlands wetlands-Review concluded Wetlands Inventory database(reviewed 05/31l2022),project activities are not in nor would they affect wetland resources.The 8-Step process for wetlands is not required.-joneal4- 05/31/2022 18:14:17 GMT Executive Qrder 12898- Completed �ow income or minority population in or near According to the Environmental Protection Environmental Justice for Low project area Agency's Environmental Justice Screening and Income and Minority Populations Mapping Tool(Version 2020),there are minority or low-income populations within 1 mile of the project area. The activities associated with this project will not result in any disproportionately high and adverse impacts on low income or minority populations.-joneai4-05/31l2022 18:14:27 GMT Completed No disproportionately high and adverse impact on low income or minority population- Review concluded NOTE:All times are GMT using a 24-haur clock. Page 2 oi 4 06/10(2022 F L Y Y REG01 16:34:59 REcoR oF ENv' oNnnENTAL coNsiDE�ATio�( Ec) Project HMGP-4382-0004-CA(4382-143-04)(2) Title� Foothill Water Treatment Plant Generator(Phase 2) Environmental Law/ Executive Order Status Description Comment Endangered Species Act(ESA) Completed Listed species andlor designated critical The proposed project will not destroy or habitat present in areas affected directly ar adversely modify suitable habitat and will not indirectly by the federal action affect any other listed or proposed species under the jurisdiction of the US Fish and Wiidlife Service or the National Marine Fisheries Service (the Services).It is therefore determined the proposed project would have"No Effect"on listed species and consultation with the Services under Section 7 of the Endangered Species Act is not required.See attached No Effect determination.-joneal4-05/31/2022 18:12:14 GMT Completed No effect to species or designated critical habitat(See comments for justification)- Review conciuded Farmland Protection Policy Act Completed Project does not affect designated prime or The project is located in Urban or Built-up�and (FPPA) unique farmland-Review concluded and Other Land categories according to the California lmportant Farmland Finder.As a result,the project would not result in the conversion of,or other adverse impacts to,prime or unique farmland.-joneal4-05/31/2022 18:13:16 GMT Fish and Wildlife Coordination Completed Project does not affect,conirol,or modify a Act(FWCA) waterway/body of water-Review concluded Migrakory Bird Treaty Act(MBTA) Completed Praject located within a flyway zone The project is in the Pacific Flyway;however, based on the activities associated with this scope of work,there is no potential for take of migratory birds.-joneal4-05(31/2022 18:13:31 GMT Completed Project does not have potential to take migratory birds-Review cancluded Magnuson-Stevens Fishery Completed Project not located in or near Essential Fish Conservation and Management Habitat-Review concluded Act(MSA) National Historic Preservation Act Completed ApplicabBe executed Programmatic The Undertaking was reviewed by Allison Miller (NNPA) Agreement.Activity meets Programmatic Simonds,who meets the applicable Secretary of Allowance(enter date and#in comments)- the Interior Professional Qualifications in Review concluded accordance with Stipulation I.B.1.a.of the Programmatic Agreement among the Federal Emergency Management Agency(FEMA),State Historic Preservation Office(SHPO)and California Office of Emergency Services(Cal OES)signed October 30,2014.The Undertaking complies with Second Tier Programmatic Allowance(In-kind repair or replacement,or minor upgrades,elevation,andlor installation of generators, NOTE:All times are GMT using a 24-haur clock. Page 3 oi 4 06/10(2022 F L Y Y REG01 16:34:59 REcoR oF ENv' oNnnENTAL coNsiDE�ATio�( Ec) Project HMGP-4382-0004-CA(4382-143-04)(2) Title� Foothill Water Treatment Plant Generator(Phase 2) Environmental Law/ Executive Order Status Description Comment HVAC systems,and similar equipment provided activities occur within previously disturbed soils) (Appendix B)of the Agreement.Thus,the Undertaking does not require SHPO review or notification per Stipulation II.A.1.of the Agreement.-joneal4-05l31I2022 18:23:43 GMT Wild and Scenic Rivers Act Gompleted Praject is raot alang and does not affect Wild According to the National Wild and Scenic River (WSR) and Scenic River-Review concluded System database,the closest National Wild and Scenic River is more than 22 miles northwest of the project area.There would be na impact and no further analysis is n2eded.-joneal4- 05l31/2022 18:13:49 GMT CON ITION$ Standard Conditions: Any change to the approved scope of wark will require re-evaluation for compliance with NEPA and other Laws and Executive Orders. This review does not address all federal,state and local requirements.Acceptance of federal funding requires recipient to comply with all federal,state and local laws.Failure to obtain all appropriate federal,state and local environmental permits and clearances may jeopardize federal funding. if ground disturbing activities occur during construction,applicant will monitor ground disturbance and if any potential archeological resources are discovered,wili immediately cease construction in that area and notify the State and FEMA. NOTE:All times are GMT using a 24-haur clock. Page 4 of 4 Resolution No. 2023 - A RESOLUTION OF THE CITY OF REDDING APPROVING AND ADOPTiNG THE 90Tx AMENDMENT TO CITY BUDGET RESOLUTION NO. 2021-078 APPROPRIATING $1,967,840 FOR THE FOOTHILL WATER TREATMENT PLANT GENERATOR PROJECT FOR FISCAL YEAR 2022-23. BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF REDDING THAT Budget Resolution No. 2021-078 be and is hereby amended as follows: FUND DNISION DESCRIPTION 1NCREASE DECREASE 143 869 Water $ 1,967,840 THAT account titles and numbers requiring adjustments by this Resolution are as follows: USE SOURCE OF FUNDS OF FUNDS Increase(Decrease)Revenue 143-869-06-2650-66 Federal Capital Grant-Water $ 1,967,840 Increase Bxpenditures 143-869-4286-20 HMGP FWTP Generator $ 1,967,840 Total $ 1,967,840 $ 1,967,840 THAT the purpose is to appropriate $1,967,840 for the Foothill Water Treatment Plant Generator Project for Fiscal Year 2022-23. I HEREBY CERTIFY that the foregoing Resolution was introduced at a regular meeting of the City Council of the City of Redding on the 20th day of June, 2023 and was duly adopted at said meeting by the following vote: AYES: COUNCIL MEMBERS: NOES: COUNCIL MEMBERS: ABSENT: COUNCIL MEMBERS: ABSTAIN: COUNCIL MEMBERS: MICHAEL DACQUISTO, Mayor ATTEST: FORM APPROVAL: PAMELA MIZE, City Clerk BARRY E. DeWALT, City Attorney